All published articles of this journal are available on ScienceDirect.

RESEARCH ARTICLE

A New Hybrid Viscoelastic Soft Tissue Model based on Meshless Method for Haptic Surgical Simulation

The Open Biomedical Engineering Journal 15 Nov 2013 RESEARCH ARTICLE DOI: 10.2174/1874120701307010116

Abstract

This paper proposes a hybrid soft tissue model that consists of a multilayer structure and many spheres for surgical simulation system based on meshless. To improve accuracy of the model, tension is added to the three-parameter viscoelastic structure that connects the two spheres. By using haptic device, the three-parameter viscoelastic model (TPM) produces accurate deformationand also has better stress-strain, stress relaxation and creep properties. Stress relaxation and creep formulas have been obtained by mathematical formula derivation. Comparing with the experimental results of the real pig liver which were reported by Evren et al. and Amy et al., the curve lines of stress-strain, stress relaxation and creep of TPM are close to the experimental data of the real liver. Simulated results show that TPM has better real-time, stability and accuracy.

Keywords: : Meshless, soft tissue model, force-feedback, viscoelasticity , haptic device, surgical simulation..